3 Core Al Teck90 Cable

  • VOLTAGE: 1000v
  • CONDUCTOR: Stranded AA-8000 Series Aluminum Alloy (ACM)
  • INSULATION: Cross-linked Polyethylene (XLPE)
  • COLOUR CODE: Black with White Numbering
  • BONDING CONDUCTOR: Stranded Bare AA-8000 Series Aluminum Alloy (ACM)
  • INNER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)
  • ARMOUR: Aluminum Interlock Armour (AIA)
  • OUTER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)

4 Core Al Teck90 Cable

  • VOLTAGE: 1000v
  • CONDUCTOR: Stranded AA-8000 Series Aluminum Alloy (ACM)
  • INSULATION: Cross-linked Polyethylene (XLPE)
  • COLOUR CODE: Black with White Numbering
  • BONDING CONDUCTOR: Stranded Bare AA-8000 Series Aluminum Alloy (ACM)
  • INNER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)
  • ARMOUR: Aluminum Interlock Armour (AIA)
  • OUTER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)

Al Conductor Teck90 Specifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

AL Conductor Teck90  Applications:

For wet and dry locations.
To be used for exposed and concealed wiring or where subjected to the weather.
For direct earth burial and service entrance above or below ground.
Use in ventilated, non-ventilated and ladder-type cable trays.
Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.

600V Copper Teck90-10AWG 12AWG 14AWG

  • CONDUCTOR: Stranded Soft Bare Copper, ASTM B8
  • INSULATION: Cross-linked Polyethylene (XLPE)
  • COLOUR CODE: Solid Black, White, Red & Blue or Black with White numbering
  • BONDING CONDUCTOR: Stranded Soft Bare Copper, ASTM B8
  • INNER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)
  • ARMOUR: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
  • OUTER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)

1000V 3 Core Copper Teck90 Cable

  • CONDUCTOR: Stranded Soft Bare Copper, ASTM B8
  • INSULATION: Cross-linked Polyethylene (XLPE)
  • COLOUR CODE: Solid Black, Red & Blue or Black with White Numbering
  • BONDING CONDUCTOR: Stranded Soft Bare Copper, ASTM B8
  • INNER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)
  • ARMOUR: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
  • OUTER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)

1000V 4 Core Copper Teck90 Cable

  • CONDUCTOR: Stranded Soft Bare Copper, ASTM B8
  • INSULATION: Cross-linked Polyethylene (XLPE)
  • COLOUR CODE: Solid Black, White, Red & Blue or Black with White numbering
  • BONDING CONDUCTOR: Stranded Soft Bare Copper, ASTM B8
  • INNER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)
  • ARMOUR: Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
  • OUTER JACKET: Low Acid Gas Polyvinyl Chloride (PVC)

pecifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact

Applications:

  • For wet and dry locations.
  • To be used for exposed and concealed wiring or where subjected to the weather.
  • For direct earth burial and service entrance above or below ground.
  • Use in ventilated, non-ventilated and ladder-type cable trays.
  • Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.